Intro
A producer of Bio-Diesel was required to weigh their reactor vessel with a remote display, which was positioned outside of the hazardous zone.
Intro
A producer of Bio-Diesel was required to weigh their reactor vessel with a remote display, which was positioned outside of the hazardous zone.
The company also wished to log the weight of the vessel as ingredients were added; one ingredient to the transesterification process is Ethanol, a highly volatile, flammable liquid.
ATEX approved strain gauges were already fitted to the reactor vessel support structure which were connected in-line to an ATEX 4-20mA load cell amplifier (ALA5). The 4 to 20mA current loop output then passed through a barrier to the safe area. One of Mantracourt’s panel instruments fitted with a current input module and RS232 serial communications module allowed connection to a PC where reactor weight values were logged in engineering units.
If you have an application requirement in the hazardous areas industry we are here to help. Please contact us.