Now shipping locally for US customers, global shipping from the UK

Image of alternative energy wind turbines in a row at sea.

Intro

An experimental wind turbine required 14 channels of strain measurement from 14 separate full Wheatstone bridges of 4 gauges.

The problem

The gauges were positioned along the surfaces of the prototype blades. The rotation of the blades and height of the turbine made a wired solution impractical accompanied by the clients request to re-use the system on several prototype blades.

The solution

The solution came in the form of 14 x waterproofed T24-ACMi with strain gauge input wireless sensor converter module. The modules all reported back to a single PC with one base station. They were all set to the same channel and provided readings 100 times per second. The T24-TK telemetry toolkit was used to monitor the data from all 14 x acquisition modules and log the data back to a CSV (comma separated variable file). Due to transmission collisions and the finite bandwidth of the telemetry system, only 25 to 30 readings were recorded from each of the 14 x acquisition modules every second, however the clients requirement was for only 10 readings per second. If a higher frequency of readings had been required, a single PC with multiple base stations on separate channels could have be deployed.

If you have an application for strain gauge signal converters or systems in the Alternative Energy industry we are here to help.  Please contact us.