ATEX Embedded Load Cell Amplifier, Strain Gauge Signal Conditioner (ICA5ATEX)

ATEX Embedded Load Cell Amplifier, Strain Gauge Signal Conditioner (ICA5ATEX)
ATEX Embedded Load Cell Amplifier, Strain Gauge Signal Conditioner (ICA5ATEX) ATEX Embedded Load Cell Amplifier, Strain Gauge Signal Conditioner (ICA5ATEX)
  • ATEX certificated strain gauge conditioner and load cell amplifier
  • Miniature PCB format for fitting inside sensors, 19mm diameter, 7.6mm height
  • 2 wire current loop 4-20mA output
  • Low interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • User selectable span and zero resistors
  • Robust design, high noise immunity & reverse polarity protected
  • Option of an in-line enclosure ATEX Embedded Load Cell Amplifier, Strain Gauge Signal Conditioner (shown on thumbnail image on left)

 

ATEX Intrinsically Safe
ICA5ATEX 4-20mA 2 wire

The ATEX Embedded Load Cell Amplifier, Strain Gauge Signal Conditioner offers a high performance in a miniature format, designed specifically for fitting inside load cells, converting a standard load cell to a mA output.

The ICA5ATEX has high stability and fast response.

Optional (ILE) in line enclosure to convert a standard load cell to a conditioned load cell output

ICA (models ICA1 - ICA6 S & H)

ICA5ATEX 4-20mA Current Output Amplifier

Electrical & Environmental
Parameter Min Typical Max Units/Notes
Supply Voltage Range 9.0 24  28 Volts
Operating Temp Range -40  - 85  ºC
Storage Temp Range -40  - 85  ºC
Reverse Polarity Protection  -30 - Volts
Measurements
Bridge Excitation 1.05  1.11  1.16  Volts Note 1
Bridge Impedance 350  1000  5000  Ohms
Bridge Sensitivity 0.5  2.5  55  mV/V Note 2
Output Load - 300  Ohms Note 3
Bandwidth DC - 1000  Hz
Zero Adjustment - ±2 %FR Note 4
Span Adjustment - ±8 - %FR
Linearity -  0.002 %FR
Temperature Stablity
Zero Temp Stability S 0.001  0.005  ±%FR/ºC
Span Temp Stability S - 0.007  0.014  ±%FR/ºC
 

FR=Full Range (16mA)

Note 1: 1000 Ohm load cell – Typically 0.53V for 350 Ohm cell
Note 2: Set by calibration resistor
Note 3: Limited by the 300Ω barrier impedance
Note 4: 1000 Ohms load cell – change R1 to suit other load cell impedances.

Note: Recommended bridge impedance is 1,000 Ohms

Note: The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms.

Environmental    
Storage Temperature -40 to +85ºC
Operating Temperature -40 to +85ºC
Relative Humidity 95% maximum non condensing 
CE Environmental Approvals European EMC Directive 2004/108/EC

 

  • product logo
  • product logo
  • product logo

Extremely high performance weight indicator in miniature pcb format, with high stability and fast response converts a standard load cell to a volt or mA output and available in optional in-line enclosure.

Documents

Software

No relevant software available

Product order options

ICA5ATEX Code
2 Wire 4-20mA ICA5ATEX

These are the following industries and applications in which this product has been used:

Q: What do the ATEX markings mean?

II 1 G Ex ia IIC T4
Tamb = -40°C to +85°C
CE0891 TRAC09ATEX1xxxX

ATEX Marking details

Explosion protection
II Equipment group: industrial
1 Equipment category: very high protection
G Hazard: gas atmosphere - zones 0,1 and 2

Certification Code details

Ex Explosion protection
ia Intrinsic safety according to EN60079-11 (previously EN 50020)
IIC Hydrogen/Acetylene gas group
T4 Temperature Classification – surface temperature <135°C

 

Q: Is a barrier needed for Zones 1 and 2?

A: Yes, a barrier is needed for all ATEX installations. Please contact us for more information.

Q: Can I embed the OEM ALA5 device into my own loadcell?

A: Yes, the ICA5ATEX amplifier is designed to fit into a pocket in a certified loadcell.
Please note: OEM customers must hold a notified body Quality Assurance Notification (QAN) and ensure that the load cell and amplifier assembly is submitted for ATEX certification by an appropriate body.

Q: Are there different mV/V settings available?

A: The sensitivity can be set between 0.5 mV/V and 55 mV/V by changing the SPAN (gain) resistor. Please enquire with our Sales team for more info.

Q: Can I extend the output cable on the ALA5?

A: Yes by use of an ATEX approved junction box.
Please note: The total cable capacitance must be taken into account and must not exceed TBD pF (pico farads).

Q: What is the maximum cable length for the load cell connections?

A: Maximum is 2 metres.

Q: What Strain Gauge parameters is the ALA5 designed for?

A: Designed for a 1k bridge, however, 350R can be used at the expense of noise and drift performance due to the reduced excitation voltage on the bridge. It is factory set for 2.5mV/V.

Q: What is ATEX?

A: The term 'ATEX' comes from the French word 'atmosphére explosibles'. It is the name commonly given to the framework for controlling explosive atmospheres and the standards of equipment and protective systems used in them. It is based on the requirements of two European Directives. One that applies to equipment manufacturers and another for its end users, both Directives came into effect on 1 July 2003.

The ATEX regulation removes the need for separate testing by joining the technical and legal standards for manufacturing of equipment that may potentially be used in explosive atmospheres .

ATEX regulations apply to all equipment intended for use in explosive atmospheres, whether electrical or mechanical, and also protective systems. Manufacturers must ensure that their products meet essential health and safely requirements and undergo appropriate conformity procedures.