Analogue Conditioner

Miniature Analogue Strain Gauge Amplifier with 4-20 mA 2 Wire Loop Powered OutputICA5S

Need to buy in volume?

Description

ICA5S – Miniature Strain Gauge Amplifier (4–20 mA Loop-Powered Output)

The ICA5S is a robust, 2-wire loop-powered analogue strain gauge amplifier designed to provide a 4–20 mA output directly from load cells, pressure sensors, and other strain-based transducers. Its compact design and rugged performance make it ideal for use in industrial environments requiring long cable runs and high noise immunity.

Engineered for industrial stability, the ICA5S offers excellent temperature compensation and reliable performance in harsh conditions. It is suited to a wide range of control and monitoring systems where simple, scalable current-loop integration is required.

The ICA range includes:

  • ICA1H, ICA2H, ICA3H, ICA4H, ICA6H – High-performance OEM amplifier variants

  • ICA5S – Industrial-grade solution for standard environments

  • The ICA5 is also available in an intrinsically safe ATEX-certified version (ICA5ATEX) for hazardous area applications.

An optional ILE (In-Line Enclosure) is available to externally house the amplifier, enabling conversion of standard load cells into conditioned-output devices without redesign.

Product Features & Benefits

  • Fits inside sensors, 19.5 mm diameter, 7.6 mm height
  • 4-20 mA 2 wire Loop Powered output
  • Non interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • User selectable span resistor
  • Robust design, of high noise immunity & reverse polarity protected
  • Option of an in-line enclosure

Specifications

Parameter
Min
Typ
Max
Units
Notes
Electrical & Environmental

 

Supply Voltage Range 7.5 24 28 Volts
Operating Current 4 20 mA 2 Wire
Operating temperature range -40 85 ºC
Storage temperature range -40 85 ºC
Reverse polarity protection

 

-30 Volts
Measurement

 

Bridge excitation 1.05 1.11 1.16 Volts 1000 Ohm load cell
Bridge impedance 350 1000 5000 Ohms Recommended bridge impedance is 1000 Ohms
Bridge sensitivity 0.5 2.5 55 mV/V The factory setting is the typical value, with other values possible via an alternate calibration resistor.
Output current range 4 20 mA
Output load 800 Ohms
Bandwidth DC 1000 Hz
Zero adjustment ±2 %FR ICA5 with 1000 Ohms load cell connected.
Span adjustment ±8 %FR
Linearity 0.02 %FR
Zero temp stability 0.001 0.005 ±%FR/ºC
Span temp stability 0.007 0.014 ±%FR/ºC
Environmental

 

Storage Temperature -40 to +85ºC
Operating Temperature -40 to +85ºC
Relative Humidity 95% maximum non condensing
CE Environmental Approvals European EMC Directive 2004/108/EC

Dimensions

19.5mm x 7.6mm

Downloads

FAQ

Q How many load cells can you attach to a ICA?
A One