Miniature Analogue Strain Gauge Amplifier with 0-10 V 3 wire OutputICA6H
Description
ICA6H – Miniature Strain Gauge Amplifier (0–10 V Output)
The ICA6H is a high-performance OEM miniature strain gauge amplifier designed to deliver a 0–10 V analogue output via a 3-wire connection. Compact and reliable, it is intended for direct integration into load cells, force sensors, and other strain-based devices where space is limited and performance is critical.
As part of the ICAH series, the ICA6H provides very high stability with low drift over a wide temperature range, ensuring precise measurement even in demanding applications. Its 0–10 V signal is ideal for integration with most standard data acquisition and control systems.
The ICA range includes:
-
ICA1H, ICA2H, ICA3H, ICA4H, ICA6H – High-performance OEM variants
-
ICA5S – Industrial-grade version for rugged installations
-
The ICA5 is also available in an intrinsically safe ATEX-certified version (ICA5ATEX) for hazardous area applications.
An optional ILE (In-Line Enclosure) enables easy external installation, converting standard load cells into fully conditioned-output transducers.
Product Features & Benefits
- Fits inside sensors, 19.5 mm diameter, 7.6 mm height
- 0-10 V 3 wire Output
- Non interaction between the trimmers makes calibration fast and easy
- High speed 1000 Hz
- User selectable span resistor
- Robust design, of high noise immunity & reverse polarity protected
- Option of an in-line enclosure
Specifications
Parameter |
Min |
Typ |
Max |
Units |
Notes |
Electrical & Environmental
|
|||||
| Supply Voltage Range | 13 | 24 | 28 | Volts | |
| Operating Current | 22 | mA | With 350 Ohm load cell connected. | ||
| Operating temperature range | -40 | – | 85 | ºC | |
| Storage temperature range | -40 | – | 85 | ºC | |
| Reverse polarity protection
|
-30 | – | – | Volts | |
Measurement
|
|||||
| Bridge excitation | 4.9 | 5 | 5.1 | Volts | |
| Bridge impedance | 350 | 1000 | 5000 | Ohms | |
| Bridge sensitivity | 0.5 | 2.5 | 150 | mV/V | The factory setting is the typical value, with other values possible via an alternate calibration resistor. |
| Output current range | -10 | – | +1001 | Volts | |
| Output load | – | – | 5000 | Ohms | |
| Bandwidth | DC | – | 1000 | Hz | |
| Zero adjustment | – | ±2 | – | %FR | |
| Span adjustment | – | ±8 | – | %FR | |
| Linearity | – | 0.02 | – | %FR | |
| Zero temp stability | – | 0.0004 | 0.0015 | ±%FR/ºC | |
| Span temp stability | – | 0.002 | 0.0051 | ±%FR/ºC |
Environmental
|
|||||
| Storage Temperature | -40 to +85ºC | ||||
| Operating Temperature | -40 to +85ºC | ||||
| Relative Humidity | 95% maximum non condensing | ||||
| CE Environmental Approvals | European EMC Directive 2004/108/EC | ||||
Dimensions
19.5mm x 7.6mm
Downloads
FAQ
| Q | How many load cells can you attach to a ICA? |
| A | One |
Need Assistance?
Get in touch and we’ll help you
to identify the right solution.