Control

Load Cell Amplifier with Relays Data Port & Display for WeighingLCA20 Base Unit

SKU: LCA20 Base Unit

Need to buy in volume?

Description

The LCA20 is a highly versatile digital load cell amplifier designed for both single and multiple load cell weighing applications. It features an easy one-pass calibration and quick setup process, making it ideal for efficient system integration. Equipped with relays, a data port, and a clear display, the LCA20 provides reliable performance across a wide range of weighing and control tasks.

This listing is for the LCA20 Base unit, please contact us for configuration options.

This advanced load cell weight indicator supports local or remote LCD displays, isolated analogue outputs (4–20 mA and 0–10 V), and relay outputs for control or alarm functions—such as crane overload protection or in-flight compensation for silo and bag-filling operations. Digital communication is available via RS232 or RS485 for setup and data exchange, with compatibility for label and ticket printers.

Offering both analogue and digital output options, setpoint control, and display functionality, the LCA20 operates from either AC or DC power and carries IP65 (NEMA 4) environmental protection.

The LCA20 replaces the earlier LCA15 model, delivering enhanced functionality, improved performance, and updated technology. It is supplied in a robust IP65 ABS bulkhead-mounting enclosure, with alternative versions available for DIN rail or PCB mounting (model LCB20).

For PCB integration, see the LCB20 Load Cell Amplifier and Digitiser.
For further details, visit our Load Cell Amplifier Application Guide or watch the LCA20 overview video on YouTube.

The LCA20 can also be paired with the LCI Load Cell Failure Alarm, a continuous monitoring system that detects load cell faults and triggers alarms—enhancing safety, minimising downtime, and reducing on-site maintenance costs.

Product Features & Benefits

  • Full digital set–up using PC or keypad
  • 3 x configurable digital inputs e.g. for autotare, peak hold and reset
  • RS485 and RS232 digital data output for communications and printing
  • Measurement speeds of 10 / 80 samples per sec
  • Factory calibration in mV/V
  • 5 V excitation supports up to 10 x 350 R load cells
  • Fully isolated 4-20 mA and 0-10 V analogue outputs
  • 6 wire input to compensate for barrier and cable losses
  • 2 set points SPCO relay outputs
  • Sensitivity from 0.5 to 7.8 mV/V
  • 10 pt linearization
  • Firmware now supports Mantrabus 1 & 2, MANTRA ASCII 2 & MODBUS RTU
  • ROHS Compliant & Environmentally sealed to IP65 / NEMA 4 enclosure dimensions 200 x 120 x 75 mm
  • Supplied in IP65 NEMA4 ABS protected case, stainless steel version or DIN Rail option. See also LCB option
  • The LCA20 shown in main photo has the transparent lid option (LTL)

Specifications

Inputs
The input is of the Load Cell/Strain Gauge type. With transducer excitation voltage of 5 volts @ 160mA to drive 10 x 350R bridges
Compensation by ± sense wires for cable and safety barrier losses down to 3V excitation
Load cell sensitivity range 0.5 to 7.8mV/V (2 ranges configured from keypad or communications port)
Initial offset is no greater than ± 0.15mV (15uV/V) which is cancelled during auto calibration
Speed 10 and 80 Samples Per Second (configured from keypad or communications port)
Factory mV/V calibration accuracy ± 0.05% FSD being typical
Drift ± 2 ppm per degree C @ 2.5 mV/V typical
Non Linearity before linearization 10 pt typical
Internal Resolution 20 bit or 1 part in 1,000,000
Noise Free Resolution @ 10 Hz 17.5 bit or 1 part in 180,000
Contact inputs are available for auto tare, print and peak hold reset and are volt free
Analogue Outputs
Drive 4-20 mA up to 1 Kohm and 0-10 volts up to 2 mA
Accuracy ± 0.15% of range, typical
Resolution as for display up to 13 bits / 4.5 digits. Settling time 350 mS to within 1% of step change
Isolation ±130 V RMS or DC max to analogue input or any other port
Power Supplies
LS1 110 V-120 V AC or 220 / 230 V AC 50-60 Hz 10 W
LS3 9-32 V DC 10 W isolated
Data Retention/Protection
Retention 20 years for set up values, minimum of 100,000 write cycles
Protection of data and function(s) Watchdog timer giving repeat auto resets. Impending power detection and hold off. Calibration and Toolkit lock feature
Other Options & Accessories
2 Set Points Output through 5 A 240 V AC SPCO Relays, with a latching option
Communications Port For data transfer or print via :-
RS485 Enabling up to 253 units to be multi dropped
RS232 For 1 to 1 connection and standard printer drive and large displays
Printer Operation By closure of volt free contact or continuous ASCII stream
Baud Rates 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200
Die Cast Case Sealed to IP65 / NEMA 4 with external dimensions of 220 x 120 x 80mm max
Stainless Steel Case Sealed to IP65 / NEMA 4 with external dimensions of 224 x 160 x 90mm
PCB Only (Eurocard) (LCB20) 100 x 160 X 57mm for rack or customers enclosure
Environmental
Storage Temperature -20 to +70ºC
Operating Temperature -10 to 50ºC
Relative Humidity 95% maximum non condensing
CE Environmental Approvals European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC

Dimensions

Product order options

Please read the following before selecting the options for this product:

LCA20 Base Unit – Standard Instrument with 4-20mA/0-10 Analogue Outputs for ABS Case.
Ordering Information- Starting with the base model LCA20 select the options that you need to configure the device to meet your needs. i.e. LCA20-LC4-LR1-LS3-LP1-LTL

Options
Code
Junction Box Active JBA
Junction Box PCB (only) Active JPA
Base Unit
Code
LCA20 LCA20
Comms
Code
RS485/232 Communications (supports MODBUS RTU, ASCII, MANTRABUS 1 & MANTRABUS 2) LC4
Relay
Code
Relay Output Module 2 Set Points (2 x SPCO 5A 240V AC ) LR1
Power Supplies
Code
AC Power Supply 110/120V, or 220/230V AC LS1
DC Power Supply 9-32V DC LS3
Display
Code
On Board Programmer LP1
Remote Hand Held Programmer LP2
Extended Mounting
Code
Transparent Plastic Case Lid LTL
Accessories
Code
PGM1 Programming Lead (no discount available) PGM1
Junction Box PCB (only) Passive JPP

Downloads

FAQ

Q What Protocols are available with the LCA20?
A There are 4 Protocols
CP=128 = Mantrabus 1 a hex based protocol. Most popular, easiest to deal with from programming point of view.
CP=131 = Mantrabus 2 updated version of Mantrabus1
CP=133 = Mantra ASCII 2 based protocol designed for old teletype machines, looks easier but actually more complicated to programme.
CP = 132 Modbus RTU used a lot in PLCs. 3rd Party S/W available. Hex based.
Or alternatively set CP=127 and the device will transmit an ASCII string every display update (used for continuous printout to either printer or display.
Q Does stainless steel case for LCA20 have stainless steel glands?
A No plastic PG9 glands.
Q Does the 4-20 mA output on an LCA20 have galvanic separation?
A No but it does have electrical isolation up to ±130V RMS
Q How do you view the live reading on the LCA20 without Auto Tare and having to calibrate again?
A Go to the ‘measurement’ section in the LCA Toolkit.
Note the reading in the ‘Tare’ value box and then change the value to zero. Click on the ‘Tare’ button and the unit will display live reading.Alternatively, using the keypad:
Go into the menu and pick AT Mnemonic.
Note the reading down and then set to zero.
Press return and then the unit will display live reading.
To reset Auto Tare re enter value in AT Mnemonic screen which you noted down.
Q What is the maximum length of cable we could connect between a LCA20 unit and a load cell unit?
A It would depend on many different factors:
The quality of the cable
The type of cable
Whether it was 4 or 6 core
The number of load cells
Environment
Interference
With the best quality of cable in an ideal environment and with little or no interference we have had operating at 200 metres.
Q LCA20 / SMW can they handle tension and compression?
A Yes
Q Is it possible to connect two LCA20s to one load cell?
A How would the scaling of each remain stable in the event of a failure of one or the other ?
Can the output of the load cell be connected to both LCAs? With perhaps a resistor network holding the input of the second to a reference ?A: This is done using 6 wire, with the second LCA20 as 5 wire (no “+” excitation).
You could have two 6 wire with two blocking diodes (for redundancy).
Or a separate power supply and two 5 wires.
Q How do I factory reset a ADP / ADW / LCA20 / SMW?
A Hold down the Scroll and reset key and then power cycle the unit.
* All settings will be reset, including calibration.
Q Can I use a laptop to set up the LCA20?
A Yes, by means of the optional PGM1 Programming Cable and the LCA Toolkit. The option to use the LCA20 keypad is also available.

Need Assistance?
Get in touch and we’ll help you
to identify the right solution.