Analogue Conditioner

Miniature Analogue Strain Gauge Amplifier with ± 10 V 4 wire OutputICA3H

Need to buy in volume?

Description

ICA3H – Miniature Strain Gauge Amplifier (±10 V Output)

The ICA3H is a high-stability miniature strain gauge amplifier designed for seamless OEM integration into load cells, force sensors, and other strain-based transducers. It delivers a ±10 V analogue output over a 4-wire connection, offering excellent signal range and compatibility with standard measurement systems.

As part of the ICAH series, the ICA3H offers very high stability and minimal temperature drift, making it ideal for precision applications in industrial, automotive, and aerospace sectors. Its miniature format and robust performance make it a proven solution for embedded instrumentation.

The ICA range includes:

  • ICA1H, ICA2H, ICA3H, ICA4H, ICA6H – High-performance OEM amplifier variants

  • ICA5S – Industrial-grade stability for general-purpose use

  • The ICA5 is also available in an intrinsically safe ATEX-certified version (ICA5ATEX) for hazardous area applications.

An optional ILE (In-Line Enclosure) allows external installation to convert standard load cells into conditioned-output sensors.

Product Features & Benefits

  • Fits inside sensors, 19.5 mm diameter, 7.6 mm height
  • ± 10 V 4 wire Output
  • Non interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • User selectable span resistor
  • Robust design, of high noise immunity & reverse polarity protected
  • Option of an in-line enclosure

Specifications

Parameter
Min
Typ
Max
Units
Notes
Electrical & Environmental

 

Supply Voltage Range ±13 ±14 ±15 Volts
Operating Current 22 mA With 350 Ohm load cell connected.
Operating temperature range -40 85 ºC
Storage temperature range -40 85 ºC
Reverse polarity protection

 

-30 Volts
Measurement

 

Bridge excitation 4.9 5 5.1 Volts
Bridge impedance 350 1000 5000 Ohms
Bridge sensitivity 0.5 2.5 150 mV/V The factory setting is the typical value, with other values possible via an alternate calibration resistor.
Output current range -10 +10 Volts
Output load 5000 Ohms
Bandwidth DC 1000 Hz
Zero adjustment ±2 %FR
Span adjustment ±8 %FR
Linearity 0.02 %FR
Zero temp stability 0.0004 0.0015 ±%FR/ºC
Span temp stability 0.002 0.0051 ±%FR/ºC
Environmental

 

Storage Temperature -40 to +85ºC
Operating Temperature -40 to +85ºC
Relative Humidity 95% maximum non condensing
CE Environmental Approvals European EMC Directive 2004/108/EC

Dimensions

19.5mm x 7.6mm

Downloads

FAQ

Q How many load cells can you attach to a ICA?
A One

Need Assistance?
Get in touch and we’ll help you
to identify the right solution.