Analogue Conditioner

Miniature Analogue Strain Gauge Amplifier with 0-10 V 3 wire OutputICA6H

Need to buy in volume?

Description

ICA6H – Miniature Strain Gauge Amplifier (0–10 V Output)

The ICA6H is a high-performance OEM miniature strain gauge amplifier designed to deliver a 0–10 V analogue output via a 3-wire connection. Compact and reliable, it is intended for direct integration into load cells, force sensors, and other strain-based devices where space is limited and performance is critical.

As part of the ICAH series, the ICA6H provides very high stability with low drift over a wide temperature range, ensuring precise measurement even in demanding applications. Its 0–10 V signal is ideal for integration with most standard data acquisition and control systems.

The ICA range includes:

  • ICA1H, ICA2H, ICA3H, ICA4H, ICA6H – High-performance OEM variants

  • ICA5S – Industrial-grade version for rugged installations

  • The ICA5 is also available in an intrinsically safe ATEX-certified version (ICA5ATEX) for hazardous area applications.

An optional ILE (In-Line Enclosure) enables easy external installation, converting standard load cells into fully conditioned-output transducers.

Product Features & Benefits

  • Fits inside sensors, 19.5 mm diameter, 7.6 mm height
  •  0-10 V 3 wire Output
  • Non interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • User selectable span resistor
  • Robust design, of high noise immunity & reverse polarity protected
  • Option of an in-line enclosure

Specifications

Parameter
Min
Typ
Max
Units
Notes
Electrical & Environmental

 

Supply Voltage Range 13 24 28 Volts
Operating Current 22 mA With 350 Ohm load cell connected.
Operating temperature range -40 85 ºC
Storage temperature range -40 85 ºC
Reverse polarity protection

 

-30 Volts
Measurement

 

Bridge excitation 4.9 5 5.1 Volts
Bridge impedance 350 1000 5000 Ohms
Bridge sensitivity 0.5 2.5 150 mV/V The factory setting is the typical value, with other values possible via an alternate calibration resistor.
Output current range -10 +1001 Volts
Output load 5000 Ohms
Bandwidth DC 1000 Hz
Zero adjustment ±2 %FR
Span adjustment ±8 %FR
Linearity 0.02 %FR
Zero temp stability 0.0004 0.0015 ±%FR/ºC
Span temp stability 0.002 0.0051 ±%FR/ºC
Environmental

 

Storage Temperature -40 to +85ºC
Operating Temperature -40 to +85ºC
Relative Humidity 95% maximum non condensing
CE Environmental Approvals European EMC Directive 2004/108/EC

Dimensions

19.5mm x 7.6mm

Downloads

FAQ

Q How many load cells can you attach to a ICA?
A One

Need Assistance?
Get in touch and we’ll help you
to identify the right solution.