Strain Gauge to USB ConverterDSCUSB
Description
The DSCUSB strain gauge to USB converterĀ is a compact, high performance strain gauge digital signal conditioner with USB connectivity aimed at applications which require high-accuracy measurement repeatability.
A rugged ABS IP50 enclosure makes this USB load cell converter suitable for all environments. Simply by plugging the DSCUSB into a PC, data can be extracted from most strain gauge bridge input sensors and acquired by software which allows data manipulation removing the need for amplifiers, filters & multimeters. No additional power supply is required as the power is drawn from the USB bus.
The strain gauge to USB converter (DSCUSB) is ideal for one to one interface, however you can connect multiple DSCUSB’s to the same PC/Laptop via a suitable hub
Ideal for all strain gauge bridge based sensors including load, weight, force, torque, pressure & displacement, the device simply plugs into your PC where data can be acquired and manipulated byĀ accompanying software.
Typical applications for the DSCUSB USB load cell signal converter will be those requiring simple sensor connectivity in desk top settings such as test & measurement, R&D and laboratory environments.
An optional temperature sensor module (DTEMP) is available which will enable an advanced 5-point temperature compensation of measurements.
The USB load cell signal converter is also available as OEM pcb modules
DSCUSB is a direct replacent for the legacy product DSC (S&H) UEASC & DSC (S&H) UASC
Product Features & Benefits
- High stability providing superior performance
- USB strain gauge interface ā device appears as a virtual com port
- Simple & easy to connect to your strain gauge sensor
- Multiple devices can be used with one PC
- Supplied with 1.5m USB to Micro USB lead
- Free DSCUSB strain gauge to USB converter toolkit software
- Compatible with most load cells and sensors
- Non-expert maintenance
- Windows driver DLLās available
- OEM pcb versions available
Specifications
Parameter
|
|
| Strain Gauge Measurement | 4 Wire |
| Strain Gauge Excitation Voltage | 5 V dc |
| Strain Gauge Drive Capability | 85 ohms |
| Strain Gauge Sensitivity | ±3 mV/V or ±4.5 mV/V |
| Offset Temperature Stability | 4 ppm / ĀŗC |
| Gain Temperature Stability | 5 ppm / ĀŗC |
| Non Linearity before Linearization | 25 ppm of FR |
| Internal Resolution | 16 Million Counts/divs |
| Resolution @ 1Hz readings (Noise stable) over 100s |
200,000 Counts/divs |
| Resolution @ 10Hz readings (Noise stable) over 100s |
120,000 Counts/divs |
| Resolution @ 100Hz readings (Noise stable) over 100s | 50,000 Counts/divs |
Electrical
|
|
| Power Supply Voltage (USB) |
5 V dc |
| Power Supply Current (350 Ohm Bridge
|
68 mA |
Data Transmission
|
|
| Maximum Output Cable Length | 5 m |
| Data Transmission Rate | 115.200 kbps |
Environmental |
|
| Operating temperature range | -40 to +85 ĀŗC |
| Storage temperature range | -40 to +85 ĀŗC |
| Maximum Humidity | 95% RH |
| Protection | IP50 |
Dimensions
Cased Version; 70.5 x 51 x 20mm excluding 9-way āDā type socket connector (74.5 x 51 x 20mm including connector).
Downloads
FAQ
| Q | How do I communicate with the USB device? |
| A | Using a simple āVirtual Com Portā, the DSCUSB communicates as if the device is connected to a serial port. The device addressing allows multiple devices. |
| Q | Is temperature sensing available on the DSCUSB? |
| A | An optional temperature sensor module (DTEMP) is available which will enable an advanced 5-point temperature-compensation of measurements. |
| Q | Is there Linearity compensation in the DSCUSB? |
| A | Advanced 7-point linearity compensation available as standard. |
| Q | How stable is the DSCUSB device? |
| A | 10ppm/°C basic accuracy (equates to 16 bit resolution). |
| Q | Are there self-diagnostics capabilities? |
| A | Continuous monitoring on the DSCUSBĀ for faults such as strain overload, over/under-temperature, broken sensors orĀ power failure. All fault warnings are retained on power-fail. |
| Q | What are the output options of the DSCUSB? |
| A | We currenly only offer the device in ASCII protocol. |
| Q | Tell me about DSCUSB low current |
| A | Functions as a āLow Power Deviceā i.e. draws less than 100mA (one unit load) when connected to a 350 Ohm Bridge. |
Need Assistance?
Get in touch and weāll help you
to identify the right solution.